NetBackup status code: 103 ( Error Occurred During Initialization, check configuration file)


NetBackup status code: 103
Message: error occurred during initialization, check configuration file


Explanation: NetBackup Snapshot Client can perform two kinds of off-host backups by means of a data mover: the NetBackup media server method or the Third-Party
Copy Device method. For either method, an off-host data mover backup requires a configuration file (the 3pc.conf file) to identify the following devices on the SAN:
■ The client disks to back up
■ The devices on which to store the data 


If the media server has access to many disks and storage devices on the SAN, it may take too long to acquire the device information from the SAN. As a result, if no 3pc.conf file exists on the media server, the first multistream backup that uses a data mover method may fail.

Recommended Action: Create the 3pc.conf file manually before running the first multistream data mover backup. Use the following command to create the 3pc.conf file:
# bptpcinfo -a
The 3pc.conf file is created at /usr/openv/volmgr/database/3pc.conf. More information is available on the 3pc.conf file and how to create it.
See Configuring NetBackup for off-host data mover backups in the NetBackup Snapshot Client Configuration document.


Source : www.veritas.com
Labels: Netbackup, StatusCode

Thanks for reading NetBackup status code: 103 ( Error Occurred During Initialization, check configuration file). Please share...!

0 Komentar untuk "NetBackup status code: 103 ( Error Occurred During Initialization, check configuration file)"
Back To Top